Support

Ending a cable shield at a Garmin D-sub backshell: the window, flat braid and ring terminal the G3X manual calls for

Garmin's G3X manual ends each cable shield on a flat braid that runs to a ring terminal on the backshell's shield block. It gives the window and float lengths for each shell size, prefers solder sleeves, limits each braid to 4 inches and each tapped hole to two ring terminals, and calls for flat braid so the conductor can be inspected. Jackscrews take 6 to 8 inch-pounds.

28 Nov 2026

A builder who has crimped every contact in a G3X harness still has the shields to deal with. Each shielded cable that comes into a D-sub connector has a braid under its jacket, and that braid has to end somewhere, connected, inspectable and out of the way of the pins. Garmin's answer is the metal backshell itself: its jackscrew backshells carry what the manual calls "a convenient shield block for grounding the cable shields," and each shield reaches it through a short flat braid and a ring terminal.

The steps are in Section 23 of the G3X Touch installation manual, Revision BA of October 2026, pages 23-1 to 23-15. They apply to every Garmin unit in that manual that uses a jackscrew backshell. Which shields are grounded, and at which end, is set by each unit's wiring drawings in the same manual; Section 23 is about how the job is done once that's decided.

An exploded drawing of a D-sub connector backshell: the cover and its two screws, the strain relief clamp and its three screws, the housing with its jackscrews, and a shielded cable whose flat braid runs to a ring terminal held to the housing by a screw, split washer and flat washer. The drawing marks 2.5 inches at most from the edge of the socket contacts to the beginning of the shield, and 0.31 inch at most of exposed shield. Picture: Hangar Debrief.
An exploded drawing of a D-sub connector backshell: the cover and its two screws, the strain relief clamp and its three screws, the housing with its jackscrews, and a shielded cable whose flat braid runs to a ring terminal held to the housing by a screw, split washer and flat washer. The drawing marks 2.5 inches at most from the edge of the socket contacts to the beginning of the shield, and 0.31 inch at most of exposed shield. Picture: Hangar Debrief.

What comes in the kit and what doesn't

Garmin's connector kits supply the cast backshell housing, the contacts, the strain relief clamp, its three 4-40 screws, the cover and its two screws (Table 23-1). The builder supplies the rest (Table 23-2):

  • Flat braid, tinned copper of 36 AWG strands, about 19 to 20 AWG equivalent, 1,000 to 1,300 circular mils.
  • Solder sleeves, or solder and Teflon heat-shrink tubing, for the termination at the cable.
  • Insulated #8 ring terminals in three sizes: MS25036-149 (18 to 22 AWG), MS25036-153 (14 to 16 AWG) and MS25036-156 (10 to 12 AWG).
  • An 8-32 x 0.312-inch pan head screw for each terminal stack (MS51957-42 stainless, or MS35206-242 cadmium-plated steel), a split washer (MS35338-137 or -42) and a flat washer (NAS1149CN832R or NAS1149FN832P).
  • Silicone fusion tape (Garmin part 249-00114-00 or similar), which the manual leaves to the installer's discretion.

The standard method: a window, then a float

Garmin calls it Method A.1. The shield is reached through a small window cut in the jacket some distance back from the end, and the end of the cable is finished separately.

Cut the window. Measured from the end of the cable, the window goes between the "Window Min" and "Window Max" distances in Table 23-3, and it's no more than 0.35 inch long. For the smallest shell (size 1, 9 or 15 pins) that's 2.75 to 5.25 inches, 4.25 ideal; for sizes 2 through 5 it's 3.0 to 5.5 inches, 4.5 ideal. The manual warns against cutting into the braid's individual strands and suggests a coaxial cable stripper, a thermal stripper or a sharp razor blade. On a connector crowded with cables, staggering the windows along that range helps.

Attach the flat braid at the window. The braid leaves the termination toward the connector. Garmin is firm that it "is not permitted to exit the rear of the termination and loop back towards the connector."

  • Preferred: a solder sleeve, shrunk with a heat gun approved for solder sleeves. Garmin names the Raychem S03 series with a thermochromic indicator and the braid already in it (S03-02-R-9035-100, S03-03-R-9035-100 and S03-04-R-9035-100), installed to Raychem procedure RCPS 100-70, and lists five heating tools Raychem recommends: HL1802E, AA-400 Super Heater, CV-1981, MiniRay and IR-1759. Separate sleeves are to M83519/1-1 through /1-5. The sleeve has to be big enough for the cable's conductors and the braid together.
  • Secondary: solder the braid to the shield, then cover it with at least 0.75 inch of Teflon heat-shrink tubing to M23053/5. The manual's warning here is the one that matters: too much heat can burn through the center conductors' insulation "and shorts the shield to the signal wire."

Finish the end (the float). At the same end of the cable, strip back jacket and shield together by the "Float" length in Table 23-3: 1.25 to 2.25 inches (1.75 ideal) for a size 1 shell, 1.5 to 2.5 inches (2.0 ideal) for the others. Garmin prefers that jacket and shield be cut at the same point so no shield shows, covered by at least 0.75 inch of Teflon heat shrink. The alternative is to leave no more than 0.35 inch of shield, fold it back over the jacket and cover it with a solder sleeve.

Crimp the contacts. About 0.17 inch of insulation comes off each conductor, the wire must show in the contact's inspection hole, and the insulation ends 1/64 to 1/32 inch from the contact. Hangar Debrief's article on crimping D-sub pins covers the tools.

The braid and the ring terminal

The flat braid is cut so that, with its ring terminal, it reaches one of the tapped holes in the backshell, with enough slack to move with the bundle and no loop. The manual sets the window so the braid is no more than 4 inches long.

The ring terminals follow fixed limits (step 8 of Section 23.2.3):

  • Each tapped hole takes no more than two ring terminals.
  • Two braids to a ring terminal is preferred, which calls for the 14 to 16 AWG terminal, MS25036-153.
  • A single braid goes in the 18 to 22 AWG terminal, MS25036-149.
  • Three braids to one terminal is permitted when there are too many shields, in the 10 to 12 AWG terminal, MS25036-156.

On the 8-32 screw the stack goes, in this order from the head: split washer, flat washer, first ring terminal, second ring terminal if there is one. Then the screw goes into the shield block.

Why flat braid and not a length of insulated wire? Garmin's note says it is specified "to allow continuing air worthiness by allowing for visual inspection of the conductor." The one place the manual reverses that is the ground strap for an ID program pin, which configures a unit: there it calls for a 4-inch length of 22 AWG insulated wire, and its warning says flat braid "is not permitted for this purpose" because an exposed conductor could cause a ground where none is wanted.

When there are too many shields

Two variations exist for crowded connectors. Daisy chaining (Methods A.2 and B.2) lets a maximum of two shields be joined in series before reaching the ring terminal, "in rare situations" where there are more than three braids per terminal, with the combined braids about 4 inches long at most.

Quick Term (Method B.1) combines the window and the float into one termination at the end of the cable: strip 1.5 to 2.5 inches of jacket (1.25 to 2.25 for a size 1 shell, Table 23-4), trim the shield to no more than 0.35 inch, fold it back over the jacket and attach the braid there. It saves a step, but Garmin explains that the original reason for separating the two terminations was to spread them along the bundle so they don't "bunch up," and that with Quick Term "care must be taken to make sure that all drain shield terminations can still be inspected." For a connector with many shields, the manual says Method A may be best.

A signal wire spliced inside this area (Section 23.2.9) is spliced within a 3-inch window outside the strain relief, never inside the backshell, so the pin can still be extracted and the splice isn't preloaded.

Closing it up

  • Wrap the bundle with silicone fusion tape where the clamp and housing meet it, if the builder chooses to.
  • Put the smooth side of the strain relief clamp across the bundle. The manual's warning: the grooved side "may risk damage to wires."
  • Fit the cover with its two screws.
  • Tighten the jackscrews to the unit at 6 to 8 inch-pounds, preferably with a 3/32-inch hex driver, and never more than 8. They're drilled for safety wire, but the manual says that "is generally not a requirement," especially with a hex tool. A loose connector, it notes, "may cause vibration-related performance issues that are difficult to troubleshoot."

Garmin points to FAA AC 43.13-1B, chapter 11, section 8, as a helpful reference for termination techniques. For the Garmin boxes themselves, the manual's numbers are the ones to build to.

Sources

Picture: an exploded drawing of a D-sub backshell, supplied by the owner of Hangar Debrief on Nov. 27, 2026. Its source is not named with it. The figures in this article are from the manual's text and tables, Revision BA. Picture: Hangar Debrief.

For information only. Not approved data. Follow the manufacturer's instructions and the regulations.

Source: static.garmin.com

All articles